Motor starter/Motor starter combination Eaton Rapid Link
Add to selection
General information
Ordercode YESSS
6090-8641 
Product code
198526 
EAN code
4015081964017
Product group
Motor starter/Motor starter combination
Brand
Eaton
Serie
Rapid Link
Type
RAMO5-D204A32-512RS1
Direktstarter, 6.6 A, Sensor-Eingang 2, 400/480 V AC, AS-Interface®, S-7.A.E.
Direktstarter, 6.6 A, Sensor-Eingang 2, 400/480 V AC, AS-Interface®, S-7.A.E. für 62 Teilnehmer, HAN Q5, mit Reparaturschalter
Product description
DOL starter, 6.6 A, Sensor input 2, 400/480 V AC, AS-Interface®, S-7.A.E. for 62 modules, HAN Q5, with manual override switch
Product specifications
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage at AC 50 Hz
0 - 0 V
Overload release current setting
0.3 - 6.6 A
Type of electrical connection of main circuit
Plug-in connection
Degree of protection (IP)
IP65
Rated control supply voltage at AC 60 Hz
0 - 0 V
Rated control supply voltage at DC
0 - 0 V
Rated operation power at AC-3, 230 V, 3-phase
0 kW
Voltage type for actuating
DC
Rated operation power at AC-3, 400 V
3 kW
Rated power, 460 V, 60 Hz, 3-phase
2.238 kW
Rated power, 575 V, 60 Hz, 3-phase
0 kW
Rated operation current Ie
6.6 A
With short-circuit release
Yes
Rated operation current at AC-3, 400 V
6.6 A
Rated conditional short-circuit current, type 1, 480 Y/277 V
10000 A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0 A
Rated conditional short-circuit current, type 2, 230 V
0 A
Rated conditional short-circuit current, type 2, 400 V
0 A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Ambient temperature, upper operating limit
55 °C
Temperature compensated overload protection
Yes
Release class
CLASS 10 A
Type of electrical connection for auxiliary- and control current circuit
Plug-in connection
Rail mounting possible
No
With transformer
No
Number of command positions
1
Supporting protocol for TCP/IP
No
Suitable for emergency stop
No
Supporting protocol for PROFIBUS
No
Coordination class according to IEC 60947-4-3
Class 1
Supporting protocol for CAN
No
Number of indicator lights
0
Supporting protocol for INTERBUS
No
External reset possible
Yes
Supporting protocol for ASI
Yes
With fuse
No
Supporting protocol for MODBUS
No
Supporting protocol for Data-Highway
No
Degree of protection (NEMA)
12
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Width
220 mm
Height
270 mm
Depth
120 mm
Power consumption
8 W
Product information