Device for monitoring of safety-related circuits Eaton ESR

Add to selection
General information
Ordercode YESSS
0509-2043
Product code
118705
EAN code
4015081168453
Product group
Device for monitoring of safety-related circuits
Brand
Eaton
Serie
ESR
Type
ESR5-NV3-30
Sicherheitsrelais zur NOT-HALT-/Schutztür-/Lichtgitter-Überwachung, 24VDC, 4 Freigabepfade(2verz.) Sicherheitsrelais zur NOT-HALT-/Schutztür-/Lichtgitter-Überwachung, 24VDC, 4 Freigabepfade(2verz.)
Product description

Safety relay dual-channel, off-delayed, for implementing the basic functions emergency switching off, emergency stop, and light curtain, supply voltage 24VDC, 2 Enable current paths (IEC/EN 60204 Stop category 0), 2 Enable current paths (IEC/EN 60204 Stop category 1), 1 signal current path, busbar tag shroud to EN 50274 with vertical actuation from the front finger- and back-of-hand proof, suitable for cat. 4 according to EN 954-1 / PL e according to EN ISO 13849-1 / SILCL3 according to IEC 62061 / SIL3 only for High-Demand requirements, degree of protection IP20, installation location IP54 minimum, TÜV tested , rated impulse voltage 4 kV / basic isolation

Product specifications
Number of outputs, safety related, undelayed, with contact
2
Suitable for monitoring of position switches
Yes
Number of outputs, safety related, delayed, with contact
2
Delay-on energization time
0 - 0 s
Rail mounting possible
Yes
Model
Basic device
Suitable for monitoring of emergency-stop circuits
Yes
Suitable for monitoring of valves
No
Suitable for monitoring of optoelectronic protection equipment
Yes
Suitable for monitoring of tactile sensors
No
Suitable for monitoring of magnetic switches
No
Suitable for monitoring of proximity switches
No
Type of electric connection
Screw connection
With detachable clamps
Yes
Evaluation inputs
One- and two-channel
With start input
Yes
Release-delay
0.1 - 30 s
With muting function
No
With feedback circuit
Yes
Number of outputs, safety related, undelayed, semiconductors
0
Number of outputs, safety related, delayed, semiconductors
0
Number of outputs, signalling function, undelayed, with contact
0
Number of outputs, signalling function, delayed, with contact
0
Number of outputs, signalling function, undelayed, semiconductors
0
Number of outputs, signalling function, delayed, semiconductors
0
Type of safety according to IEC 61496-1
None
Stop category according to IEC 60204
0
SIL according to IEC 61508
3
Performance level according to EN ISO 13849-1
Level e
With approval for BG BIA
No
With approval according to UL
Yes
Width
22.5 mm
Height
99 mm
Depth
114.5 mm
Mit TÜV-Zulassung
Yes
Power consumption
7.8 W
Voltage type of supply voltage
AC
Supply voltage AC 50 Hz
0 - 0 V
Supply voltage AC 60 Hz
0 - 0 V
Supply voltage DC
24 - 24 V
Type of control voltage 1
DC
Control voltage 1
24 - 24 V
Type of control voltage 2
DC
Control voltage 2
24 - 24 V
Voltage type (operating voltage)
DC
Operating voltage at AC 50 Hz
0 - 0 V
Operating voltage at AC 60 Hz
0 - 0 V
Operating voltage at DC
24 - 24 V
Rated switch current
5 A
more specifications
^