Motor starter/Motor starter combination Eaton EMS2

Add to selection
General information
Ordercode YESSS
6094-0401
Product code
197166
EAN code
4015080896074
Product group
Motor starter/Motor starter combination
Brand
Eaton
Serie
EMS2
Type
EMS2-DOS-Z-9-24VDC
Direktstarter, 24 V DC, 1,5 - 7 (AC-53a), 9 (AC-51) Direktstarter, 24 V DC, 1,5 - 7 (AC-53a), 9 (AC-51) A, Schraubklemmen, NOT-HALT, PTB 19 ATEX 3000
Product description

DOL starter, Product range: Electronic motor starter, Description: DOL starting, Motor protection, Emergency-stop actuator, Circuit design: safety output stage with bypass, three-phase disconnect., Conformity, Approval Explosion protection (according to ATEX 94/9/EC): II (2) G [Ex e] [Ex d] [Ex px], II (2) D [Ex t] [Ex p], Conformity, Approval EC-prototype test certification: PTB 13 ATEX 3003, Max. motor rating for three-phase motors, 50 - 60 Hz AC-53a 380 V 400 V 415 V: P= 0.55 - 3 kW, Setting range of overload releases: Ir= 1,5 - 9 A_x, Actuating voltage: 24 V DC, Connection technique: Screw terminals , Stop Function: Controlled stop, Connection to SmartWire-DT: no, Mounting position: Vertical, Motor feeder at bottom, Standards: IEC/EN 60947-4-2, IEC 61508, ISO 13849, UL508

Product specifications
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage AC 50 Hz
0 - 0 V
Overload release current setting
1.5 - 9 A
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP)
IP20
Rated control supply voltage AC 60 Hz
0 - 0 V
Rated control supply voltage DC
24 - 24 V
Rated operation power at AC-3, 230 V, 3-phase
1.5 kW
Voltage type for actuating
DC
Rated operation power at AC-3, 400 V
3 kW
Rated power, 460 V, 60 Hz, 3-phase
0 kW
Rated power, 575 V, 60 Hz, 3-phase
0 kW
Rated operation current Ie
9 A
With short-circuit release
No
Rated operation current at AC-3, 400 V
7 A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0 A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0 A
Rated conditional short-circuit current, type 2, 230 V
0 A
Rated conditional short-circuit current, type 2, 400 V
0 A
Number of auxiliary contacts as normally open contact
1
Number of auxiliary contacts as normally closed contact
1
Ambient temperature, upper operating limit
70 °C
Temperature compensated overload protection
Yes
Release class
CLASS 10 A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Suitable for rail mounting
Yes
With transformer
No
Number of command positions
0
Supporting protocol for TCP/IP
No
Suitable for emergency stop
No
Supporting protocol for PROFIBUS
No
Coordination class according to IEC 60947-4-3
Class 1
Supporting protocol for CAN
No
Number of indicator lights
0
Supporting protocol for INTERBUS
No
External reset possible
No
Supporting protocol for ASI
No
With fuse
No
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Degree of protection (NEMA)
Other
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Width
22.5 mm
Height
99 mm
Depth
114.5 mm
Power consumption
12 W
more specifications
^